Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 35
Filter
1.
Rev. bras. ortop ; 57(5): 884-890, Sept.-Oct. 2022. graf
Article in English | LILACS | ID: biblio-1407688

ABSTRACT

Abstract This article presents a comparison between two cases in which there was a need for revision of total hip arthroplasty due to aseptic acetabular failure. We used 3D prototyping in one of the cases to perform an unconventional technique of molding synthesis material before the procedure to evaluate the time saved in the transoperative period in complex cases.


Resumo Este artigo apresenta uma comparação entre dois casos em que havia a necessidade de revisão de artroplastia total de quadril por falha acetabular asséptica. Utilizamos prototipagem em 3D em um dos casos para realizar uma técnica não convencional de moldagem de material de síntese antes do procedimento, com objetivo de avaliar o tempo economizado no transoperatório em casos complexos.


Subject(s)
Humans , Male , Female , Middle Aged , Arthroplasty, Replacement, Hip , Printing, Three-Dimensional , Models, Anatomic
2.
Rev. bras. ortop ; 57(4): 656-660, Jul.-Aug. 2022. tab, graf
Article in English | LILACS | ID: biblio-1394870

ABSTRACT

Abstract Objective To demonstrate the greater accuracy of panoramic radiographs of the lower limbs (long) in relation to short radiographs of the knee in the measurement of the mechanical axis of the lower limb after total knee arthroplasty (TKA). Methods A retrospective study was conducted to evaluate the accuracy of long and short postoperative radiographic images of 70 patients submitted to TKA in our service. The images were analyzed at random, at different times, by three orthopedists. In all images, the mechanical axis of the limb, femur and tibia were traced and femorotibial angles (FTAs) were calculated. The intraclass correlation coefficient (ICC) was calculated to evaluate the agreement of the measurement of the inter- and intra-observer mechanical axis. Results It was observed that there was high intra and interobserver agreement when panoramic radiographs were used, with minimum intra and interobserver ICC of 0.89, equivalent to a very strong agreement. On short radiographs in the anteroposterior incidence (AP) of the knee, the ICC showed moderate agreement, obtaining a maximum value of 0.75. Conclusion There is a significant difference in accuracy for the measurement of the mechanical axis of the lower limb, comparing long and short radiographs of the lower limb. Thus, for the proper measurement of the mechanical axis of the lower limb, we suggest the performance of long radiography in the postoperative period of TKA.


Resumo Objetivo Demonstrar a maior acurácia das radiografias panorâmicas de membros inferiores (longas) em relação às radiografias curtas do joelho na medida do eixo mecânico do membro inferior após a artroplastia total de joelho (ATJ). Métodos Foi realizado um estudo retrospectivo para avaliar a acurácia de imagens radiográficas longas e curtas pós-operatórias de 70 pacientes submetidos à ATJ em nosso serviço. As imagens foram analisadas ao acaso, em momentos distintos, por três ortopedistas. Em todas as imagens, o eixo mecânico do membro, do fêmur e da tíbia foram traçado,s e os ângulos femorotibiais (AFTs) foram calculados. O coeficiente de correlação intraclasse (CCI) foi calculado para avaliar a concordância da medida do eixo mecânico inter e intraobservador. Resultados Observou-se que houve alta concordância intra e interobservador quando utilizamos radiografias panorâmicas, apresentando CCI mínimo intrae interobservador de 0,89, equivalente a uma concordância fortíssima. Já nas radiografias curtas na incidência anteroposterior (AP) do joelho, o CCI mostrou-se com concordância moderada, obtendo valor máximo de 0,75. Conclusão Existe uma diferença significativa na acurácia para a medida do eixo mecânico do membro inferior, comparando-se radiografias longas e curtas do membro inferior. Assim, para a adequada mensuração do eixo mecânico do membro inferior, sugerimos a realização de radiografia longa no pós-operatório de ATJ.


Subject(s)
Humans , Postoperative Period , Retrospective Studies , Arthroplasty, Replacement, Knee , Knee/pathology , Knee/diagnostic imaging
3.
Acta ortop. bras ; 30(3): e243763, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1374151

ABSTRACT

ABSTRACT Objective: To correlate vertical (VFO) and horizontal (HFO) femoral offset with hip range of motion (ROM), peak muscle torque (PT), functional, capacity, and lower limb length in patients with total hip arthroplasty (THA). Methods: A cross-sectional case control study, in which 22 individuals (10 men and 12 women) - aged 61 (41-72), and within 23 (10-40) postoperative days - were evaluated for active hip ROM (fleximetry); Isometric PT (portable dynamometer); functional capacity (Timed up and Go test (TUG) and Harris Hip Score questionnaire); lower limb length (measuring tape); and VFO and HFO (radiographs). Results: The operated limb showed a reduction in length (p = 0.006), ROM for abduction (p = 0.001), flexion (p = 0.003), and external rotation (p = 0.003), as well as in all PT (p < 0.05) when compared with the contralateral limb. Moderate correlations were observed between VFO and external rotators (r = 0.487; p = 0.021); HFO and external rotators PT (r = −0.508; p = 0.016); and the difference between the VFO (operated and non-operated limb) and the TUG (r = −0.570; p = 0.006). Conclusion: Changes to the femoral offset seem to influence functional capacity, as well as the movement and external rotators PT of the hips in patients with THA, considering the postoperative period evaluated. Level of Evidence III, Case Control Study.


RESUMO Objetivo: Correlacionar achados do offset femoral vertical (OFV) e horizontal (OFH) aos da amplitude de movimento do quadril (ADM), pico de torque muscular (PT), capacidade funcional (CF) e comprimento dos membros inferiores (CM) em pacientes com artroplastia total de quadril (ATQ). Métodos: Estudo transversal, caso controle (nível de evidência III), foram avaliados 22 indivíduos (10 homens e 12 mulheres) com idade de 61 (41-72) anos e 23 (10-40) dias de pós-operatório, quanto à: ADM ativa do quadril (fleximetria); PT isométrico (dinamômetro portátil); CF - teste Timed up and Go (TUG) e questionário Harris Hip Score (HHS); CM (fita métrica); e OFV e OFH a partir de radiografias. Resultados: O membro operado apresentou redução no CM (p = 0,006), ADM de abdução (p = 0,001), flexão (p = 0,003) e RE (p = 0,003), e em todos os PT (p < 0,05) em comparação ao membro contralateral. Correlações moderadas encontradas entre: OFV e RE (r = 0,487; p = 0,021); OFH e PT dos RE (r = −0,508; p = 0,016); e a diferença do OFV (membro operado e não operado) e o TUG (r = −0,570; p = 0,006). Conclusão: Alterações no OF parecem influenciar a CF, bem como o movimento e o PT dos RE do quadril em pacientes com ATQ para o período pós-operatório avaliado. Nível de Evidência III, Estudo de Caso-Controle.

4.
Rev. bras. ortop ; 56(6): 809-812, Nov.-Dec. 2021. graf
Article in English | LILACS | ID: biblio-1357138

ABSTRACT

Abstract The present study aims to demonstrate how biomodels can be used as teaching tools for surgical techniques and training in a medical residency service. A case series was carried out in our orthopedics and traumatology outpatient facility using three-dimensional (3D) printing for surgical planning to contribute to the surgical teaching and training of resident physicians. Two cases were selected as examples in the present article. Biomodels enable a better understanding of the surgery by the surgical team and residents, reducing the surgical time and the risks for the patients. These models can be a good teaching method to plan reconstructions of total hip arthroplasties, evaluate and predict surgical difficulties, and optimize procedures.


Resumo O objetivo deste trabalho é demonstrar como os biomodelos podem servir como ferramenta de ensino para o esclarecimento de técnicas cirúrgicas e o treinamento em um serviço de residência médica. Foram realizadas séries de casos em nosso ambulatório de ortopedia e traumatologia, nos quais o uso da prototipagem para o planejamento cirúrgico contribuiu para o ensino cirúrgico e treinamento de médicos residentes. Dois casos foram selecionados como exemplo neste artigo. O uso de biomodelos permite um melhor entendimento da cirurgia pela equipe cirúrgica e pelos residentes, e diminui o tempo e os riscos cirúrgicos aos pacientes. O uso de biomodelos no planejamento de reconstruções da artroplastia total do quadril pode servir como um bom método de ensino, para a avaliação e previsão das dificuldades no momento da cirurgia, e para otimizar os procedimentos.


Subject(s)
Arthroplasty, Replacement, Hip , Printing, Three-Dimensional , Internship and Residency , Medical Staff, Hospital , Models, Anatomic
6.
Coluna/Columna ; 20(2): 127-131, Apr.-June 2021. tab, graf
Article in English | LILACS | ID: biblio-1249653

ABSTRACT

ABSTRACT Objective: To evaluate a new treatment for split fractures through fatigue tests on a swine model. Methods: Thirty lumbar spine samples (L2-L3-L4) from swine models were divided into three test groups. The first was the control group (intact vertebrae). In the second group, a bone defect was created, similar to a coronal split fracture of the vertebral body. For this, a bone defect (osteotomy) was performed in the coronal axis of the middle third of the middle lumbar vertebral body (L3), keeping the disc-ligament structures intact. In the third group, the same procedure was performed to cause bone failure, but was associated with the use of synthesis material, with pedicular fixation using 3.5 mm cannulated screws with partial thread, in order to apply compression at the fracture site, giving resistance and support to the vertebra. The groups were submitted to biomechanical fatigue tests. The number of cycles required to failure in the specimen was analyzed. Results: The use of the synthesis material increased the resistance of the fractured vertebrae to levels equal to those of the intact vertebra for low cycles with loads of 40% of the failure load, possibly losing up to 20% of their resistance for higher cycles. Conclusions: In the vertebrae in which synthetic material was used, greater resistance to a greater number of cycles for a longer period of time was observed when compared with the fractured vertebrae, suggesting that this is an interesting method for the fixation of split-type spinal fractures. Level of evidence III; Experimental Study.


RESUMO Objetivo: Avaliar um novo tratamento de fraturas do tipo separação (split) através de ensaios de fadiga em modelo suíno. Métodos: Trinta amostras de coluna lombar (L2-L3-L4) de modelos suínos foram divididas em três grupos para testes. O primeiro constituiu o grupo controle (vértebras intactas). No segundo grupo, foi criado um defeito ósseo semelhante a uma fratura split coronal do corpo vertebral. Para tanto, criou-se um defeito ósseo (osteotomia) no eixo coronal do terço médio do corpo vertebral intermediário lombar (L3), mantendo as estruturas disco-ligamentares íntegras. No terceiro grupo, foi realizado o mesmo procedimento para causar a falha óssea, sendo associado o uso de material de síntese, com a fixação pedicular com parafuso canulado de 3,5 mm com rosca parcial, com objetivo de realizar compressão no foco da fratura e dar resistência e sustentação à vertebra. Os grupos foram submetidos a testes biomecânicos de fadiga. Foi analisado o número de ciclos necessários para que ocorresse a falha no corpo de prova. Resultados: O material de síntese aumenta a resistência da vértebra fraturada em níveis iguais aos da vértebra intacta para baixos ciclos e com cargas de 40% da tensão de ruptura, podendo perder até 20% de sua resistência para ciclos mais altos. Conclusões: Nas vértebras em que foi utilizado material de síntese observou-se maior resistência ao maior número de ciclos por um período mais prolongado em comparação com as vértebras apenas fraturadas, sugerindo que este é um método interessante para a fixação de fraturas do tipo split na coluna vertebral. Nível de evidência III; Estudo experimental.


RESUMEN Objetivo: Evaluar un nuevo tratamiento de fracturas lumbares del tipo separación (split) a través de ensayos de fatiga en modelo porcino. Métodos: Treinta muestras de columna lumbar (L2-L3-L4) de modelos porcinos fueron divididas en tres grupos para tests. El primero constituyó el grupo control (vértebras intactas). En el segundo grupo, fue creado un defecto óseo semejante a una fractura split coronal del cuerpo vertebral. Para tanto, se creó un defecto óseo (osteotomía) en el eje coronal del tercio medio del cuerpo vertebral intermedio lumbar (L3), manteniendo las estructuras disco-ligamentarias íntegras. En el tercer grupo, fue realizado el mismo procedimiento para causar la falla ósea, siendo asociado el uso de material de síntesis, con fijación pedicular con tornillo canulado de 3,5 mm con rosca parcial, con el objetivo de realizar compresión en el foco de la fractura y dar resistencia y sustentación a la vértebra. Los grupos fueron sometidos a tests biomecánicos de fatiga. Fue analizado el número de ciclos necesarios para que ocurriese la falla en el cuerpo de prueba. Resultados: El material de síntesis aumenta la resistencia de la vértebra fracturada en niveles iguales a los de la vértebra intacta para bajos ciclos y con cargas de 40% de la tensión de ruptura, pudiendo perder hasta 20% de su resistencia para ciclos más altos. Conclusiones: En las vértebras en que fue utilizado material de síntesis se observó mayor resistencia al mayor número de ciclos por un período más prolongado en comparación con las vértebras solamente fracturadas, sugiriendo que este es un método interesante para la fijación de fracturas de tipo split en columna vertebral. Nivel de evidencia III; Estudio experimental.


Subject(s)
Humans , Fractures, Bone , Spine , Models, Animal , Fatigue
7.
Coluna/Columna ; 20(1): 55-59, Jan.-Mar. 2021. tab, graf
Article in English | LILACS | ID: biblio-1154019

ABSTRACT

ABSTRACT Objective: This research presents a biomechanical analysis performed in the lumbar spine of a porcine animal model, considering a minimally invasive technique for the treatment of split fractures. Methods: Porcine spines were used to perform compression tests, considering three different approaches. Three groups were defined in order to verify and validate the proposed technique: a control group (1); spines with split fractures (2); and a treatment group (3). For the first group (control), spines were axially compressed until any kind of fracture occurred, in order to verify the strength of the structure. In the second group, split fractures were created to obtain the mechanical failure pattern of the model. In the third group, the split fractures were submitted to the proposed treatment, to verify the resistance achieved. The three groups were compared by means of axial compression tests. Statistical analysis was performed by ANOVA. Results: The control group (intact spine) and the treated split fracture group presented similar results (p>0.05), differing from the results for the untreated split fracture group (p<0.05). Conclusions: The tests performed in order to determine the behavior and strength of the lumbar spine when subjected to axial compression provided positive data for the development of a minimally invasive technique capable of restoring split fractures of the spine. Level of evidence III; Experimental research.


RESUMO Objetivo: Esta pesquisa apresenta uma análise biomecânica realizada na coluna lombar em modelo animal suíno, considerando uma técnica minimamente invasiva para o tratamento de fraturas vertebrais do tipo split. Métodos: Foram usadas colunas de suínos para a realização de testes de compressão, considerando três diferentes abordagens. Para verificar e validar a técnica proposta, foram definidos três grupos: grupo controle (1); colunas com fraturas do tipo split (2) e grupo tratamento (3). No o primeiro grupo (controle), as colunas foram comprimidas axialmente até que ocorresse qualquer tipo de fratura, a fim de verificar a resistência da estrutura. No segundo grupo, foram criadas fraturas do tipo split para obter o padrão de falha mecânica do modelo. No terceiro grupo, as fraturas do tipo split foram submetidas ao tratamento proposto, para verificar a resistência alcançada. Os três grupos foram comparados por meio de testes de compressão axial. A análise estatística foi realizada por ANOVA. Resultados: O grupo controle (coluna íntegra) e o grupo com fratura do tipo split tratada apresentaram resultados semelhantes (p > 0,05), diferentemente dos resultados do grupo com fratura do tipo split não tratada (p < 0,05). Conclusões: Os testes para determinar o comportamento e a força da coluna lombar quando é submetida à compressão axial forneceram dados positivos para o desenvolvimento de uma técnica minimamente invasiva capaz de restaurar fraturas tipo split da coluna vertebral. Nível de evidência III; Pesquisa experimental.


RESUMEN Objetivo: Esta investigación presenta un análisis biomecánico realizado en la columna lumbar de un modelo animal porcino, considerando una técnica mínimamente invasiva para el tratamiento de fracturas vertebrales del tipo split. Métodos: Fueron usadas columnas de porcinos para la realización de tests de compresión, considerando tres diferentes abordajes. Para verificar y validar la técnica propuesta, fueron definidos tres grupos: grupo control (1); columnas con fracturas del tipo split (2) y grupo tratamiento (3). En el primer grupo (control), las columnas fueron comprimidas axialmente hasta que ocurriera cualquier tipo de fractura, a fin de verificar la resistencia de la estructura. En el segundo grupo, fueron creadas fracturas del tipo split para obtener el patrón de falla mecánica del modelo. En el tercer grupo, las fracturas del tipo split fueron sometidas al tratamiento propuesto, para verificar la resistencia alcanzada. Los tres grupos fueron comparados por medio de tests de compresión axial. El análisis estadístico fue realizado por ANOVA. Resultados: El grupo control (columna íntegra) y el grupo con fractura del tipo split tratada presentaron resultados semejantes (p>0,05), a diferencia de los resultados del grupo con fractura del tipo Split no tratada (p<0,05). Conclusiones: Los tests para determinar el comportamiento y la fuerza de la columna lumbar cuando es sometida a la compresión axial suministraron datos positivos para el desarrollo de una técnica mínimamente invasiva, capaz de restaurar fracturas del tipo Split de la columna vertebral. Nivel de evidencia III; Investigación experimental.


Subject(s)
Humans , Spinal Injuries , Spine , Therapeutics , Spinal Fractures
8.
Rev. bras. ortop ; 55(6): 771-777, Nov.-Dec. 2020. tab, graf
Article in English | LILACS | ID: biblio-1156205

ABSTRACT

Abstract Objective To evaluate different femoral fixation devices for medial patellofemoral ligament reconstruction and compare their effectiveness regarding fixation strength up to failure in porcine knees. Methods Thirty porcine knees were used, divided into three groups of 10 knees. The removed grafts were dissected from the extensor tendons of porcine feet. In each group, the graft was fixed to the femur with an interference screw, an anchor, or adductor tenodesis. The three methods were subjected to biomechanical tests using a universal Tensile testing machine at a speed of 20 mm/minute. Results The highest average linear resistance under lateral traction occurred in group 1, "screw fixation" (185.45 ± 41.22 N), followed by group 2, "anchor fixation" (152.97 ± 49, 43 N); the lower average was observed in group 3, "tenodesis fixation" (76.69 ± 18.90 N). According to the fixed error margin (5%), there was a significant difference between groups (p < 0.001); in addition, multiple comparison tests (between group pairs) also showed significant differences. Variability was small, since the variance coefficient was lower than 33.3%. Conclusion Interference screws in bone tunnels and mountable anchors fixation with high resistance wire are strong enough for femoral fixation in porcine medial patellofemoral ligament reconstruction. Adductor tenodesis, however, was deemed fragile for such purpose.


Resumo Objetivo Avaliar diferentes dispositivos de fixação femoral na reconstrução do ligamento patelofemoral medial para comparar sua eficácia quanto à força de fixação até a falha em joelhos suínos. Métodos Foram ensaiados 30 joelhos de suínos subdivididos em 3 grupos de 10 joelhos. Os enxertos retirados foram dissecados de tendões extensores das patas dos suínos. Cada grupo teve o enxerto fixado ao fêmur com parafuso de interferência, âncora, ou tenodese no tendão adutor. Os 3 métodos foram submetidos à testes biomecânicos utilizando uma máquina universal de ensaio de tração com uma velocidade de 20 mm/min. Resultados Verificamos que a média mais elevada da resistência linear sob tração lateral (185,45 ± 41,22 N) ocorreu no grupo 1: "fixação por parafuso," seguido do grupo 2: "fixação por âncora" (152,97 ± 49,43 N), e a média foi menor no grupo 3: "fixação por tenodese" (76,69 ± 18,90 N). Para a margem de erro fixada (5%), comprovou-se a diferença significativa entre os grupos (p < 0,001) e também através dos testes de comparações múltiplas (entre os pares de grupos) verificou-se a ocorrência de diferenças significativas. A variabilidade expressada por meio do coeficiente de variação mostrou-se reduzida, já que a referida medida foi inferior a 33,3%. Conclusão O uso de parafusos de interferência no túnel ósseo de joelhos porcinos é suficientemente forte para fixação femoral na reconstrução do ligamento patelofemoral medial, assim como a fixação com âncoras montáveis com fio de alta resistência. Entretanto, a tenodese no tendão adutor mostrou-se frágil para essa finalidade.


Subject(s)
Animals , Orthopedic Fixation Devices , Swine , Tendons , Traction , Effectiveness , Biomechanical Phenomena , Bone and Bones , Suture Techniques , Transplants , Models, Animal , Tenodesis , Patellofemoral Joint , Femur , Ligaments , Methods
9.
Coluna/Columna ; 19(3): 205-208, July-Sept. 2020. tab, graf
Article in English | LILACS | ID: biblio-1133584

ABSTRACT

ABSTRACT Objective To analyze the behavior of thoracolumbar fractures of the coronal split type using the finite element method. Methods Two comparative studies were conducted through simulation of coronal split fractures in a finite model in which the first lumbar vertebra (L1) was considered to be fractured. In the first case, the fracture line was considered to have occurred in the middle of the vertebral body (50%), while in the second model, the fracture line occurred in the anterior quarter of the vertebral body (25%). The maximum von Mises stress values were compared, as well as the axial displacement between fragments of the fractured vertebra. Results The stress levels found for the fracture located at half of the vertebral body were 43% higher (264.88 MPa x 151.16 MPa) than those for the fracture located at the anterior 25% of the vertebra, and the axial displacement of the 50% fractured body was also greater (1.19 mm x 1.10 mm). Conclusions Coronal split fractures located in the anterior quarter of the vertebral body incurred less stress and displacements and are more amenable to conservative treatment than 50% fractures occurring in the middle of the vertebral body. Level of Evidence III; Experimental study.


RESUMO Objetivo Analisar o comportamento das fraturas toracolombares do tipo split coronal através de elementos finitos. Métodos Foram realizados dois estudos comparativos através da simulação de fratura do tipo split coronal, em modelo finito, considerando que a primeira vértebra lombar (L1) estava fraturada. No primeiro caso, considerou-se que o traço da fratura ocorria na metade do corpo vertebral (50%), já no segundo modelo, o traço de fratura ocorria na porção anterior do corpo (25%). Foram comparados os valores de tensão máxima segundo von Mises, assim como o deslocamento axial sofrido entre os fragmentos da vértebra fraturada. Resultados Na fratura localizada ao nível da metade do corpo vertebral, os níveis de tensões encontrados foram 43% maiores (264,88 MPa x 151,16 MPa) do que aqueles na fratura a 25% no terço anterior do corpo vertebral, em que o deslocamento axial da porção fraturada também foi mais elevado (1,19 mm x 1,10 mm). Conclusões As fraturas do tipo split coronal localizadas no quarto anterior do corpo vertebral concentram menos tensões e deslocamentos, sendo mais passíveis de tratamento conservador em comparação às fraturas que ocorrem na metade do corpo vertebral. Nível de Evidência III; Estudo experimental.


RESUMEN Objetivo Analizar el comportamiento de las fracturas toracolumbares del tipo split coronal a través de elementos finitos. Métodos Se realizaron dos estudios comparativos a través de la simulación de fractura del tipo split coronal, en modelo finito, considerando que la primera vértebra lumbar (L1) estaba fracturada. En el primer caso, se consideró que el trazo de la fractura ocurría en la mitad del cuerpo vertebral (50%), ya en el segundo modelo, el trazo de la fractura ocurría en la porción anterior del cuerpo (25%). Fueron comparados los valores de tensión máxima según von Mises, así como el desplazamiento axial sufrido entre los fragmentos de la vértebra fracturada. Resultados En la fractura localizada al nivel de la mitad del cuerpo vertebral, los niveles de tensiones encontrados fueron 43% mayores (264,88 MPa x 151,16 MPa) que aquellos en la fractura a 25% en el tercio anterior del cuerpo vertebral, en que el desplazamiento axial de la porción fracturada fue también más elevado (1,19 mm x 1,10 mm). Conclusiones Las fracturas del tipo split coronal localizadas en el cuarto anterior del cuerpo vertebral concentran menores tensiones y desplazamientos, siendo más susceptibles de tratamiento conservador en comparación a las fracturas que ocurren en la mitad del cuerpo vertebral. Nivel de Evidencia III; Estudio experimental.


Subject(s)
Humans , Spine , Tensile Strength , Spinal Fractures
10.
Rev. Col. Bras. Cir ; 47: e20202590, 2020. graf
Article in English | LILACS | ID: biblio-1136535

ABSTRACT

ABSTRACT Introduction: the number of hip fractures is estimated to increase from 1.66 million in 1990 to 6.26 million by 2050. Internal fixation is the most common surgical treatment for intertrochanteric fractures. Objectives: the objective of the present research is to describe a minimally invasive technique with a modified instrument for the treatment of stable proximal femoral trochanteric fractures using the standard DHS, classified as Tronzo types 1 and 2 (AO 31A1.2), and presenting a case series. Methods: a case was selected to present the technique. Patients operated by this technique undergo a clinical evaluation and preoperative preparation as routine. The criteria for inclusion in the study were the presence of stable fracture of the proximal femur verified by two hip specialist orthopedists, and operated by the minimally invasive technique with a modified instrument using a standard DHS. Exclusion criteria were cases of patients operated for unstable fractures, and the use of other surgical techniques. A case series of 98 patients was performed and discussed. Results: minimally invasive technique with a modified instrument using the standard DHS device can reduce bleeding, it decreases soft tissue injuries, surgical time, and hospital stay, as any other MIPO procedures. Ninety-eight patients underwent the operation (Tronzo types I and II), 59 female and 39 male, ages from 50 to 85 years old. Immediate post-operative complications were shortening of the lower limb, loss of fracture reduction, and death by clinical complications. Conclusion: the present study describes a minimally invasive surgical technique using a modified instrument to perform proximal femoral osteosynthesis for stable trochanteric fractures, using the standard DHS.


RESUMO Introdução: estima-se que o número de fraturas de quadril aumente de 1,66 milhão em 1990 para 6,26 milhões em 2050. A fixação interna é o tratamento cirúrgico mais comumente utilizado para as fraturas intertrocantéricas. Objetivos: o objetivo da presente investigação é descrever uma técnica minimamente invasiva com um instrumento modificado para o tratamento de fraturas trocantéricas femorais proximais estáveis, classificadas como tipos I e II de Tronzo (AO 31A1.2), usando o DHS padrão, e apresentar uma série de casos. Métodos: foi selecionado um caso aleatório para apresentar a técnica. Os pacientes operados por essa técnica passam por avaliação clínica e preparo pré-operatório de rotina. Os critérios para inclusão no estudo foram a presença de fratura estável do fêmur proximal, verificada por dois ortopedistas especialistas em quadril, e operada pela técnica minimamente invasiva com um instrumento modificado usando um DHS padrão. Os critérios de exclusão foram os casos de pacientes operados por fraturas instáveis e o uso de outras técnicas cirúrgicas. Uma série de casos de 98 pacientes foi realizada e é discutida. Resultados: a técnica minimamente invasiva com o instrumento modificado usando o dispositivo DHS padrão pode reduzir a hemorragia, as lesões dos tecidos moles, o tempo cirúrgico e a estadia hospitalar, tal como quaisquer outros procedimentos de osteossíntese minimamente invasivos. Noventa e oito pacientes foram operados (tipos I e II de Tronzo), 59 do sexo feminino e 39 do masculino, com idades entre 50 e 85 anos. As complicações pós-operatórias imediatas foram encurtamento do membro inferior, perda da redução da fratura e morte por complicações clínicas. Conclusão: o presente estudo descreve uma técnica cirúrgica minimamente invasiva, utilizando um instrumento modificado para realizar osteossíntese femoral proximal para fraturas trocantéricas estáveis, utilizando o DHS padrão.


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Minimally Invasive Surgical Procedures/methods , Femoral Fractures/surgery , Fracture Fixation, Internal/methods , Hip Fractures/surgery , Reference Standards , Bone Screws , Treatment Outcome , Middle Aged
11.
Rev. bras. ortop ; 54(3): 261-267, May-June 2019. tab, graf
Article in English | LILACS | ID: biblio-1013734

ABSTRACT

Abstract Objective To analyze the stability of humerus supracondylar fracture fixation with Kirschner wires comparing intramedullary and lateral (Fi), and two parallel lateral wires (FL) fixation in experimental models, to define which configuration presents greater stability. Methods A total of 72 synthetic humeri were cross-sectioned to simulate the fracture. These bones were divided into two equal groups and the fractures were fixed with parallel Kirschner wires (FL) and with a lateral and intramedullary (Fi) wire. Then, the test specimens were subjected to stress load tests on a universal test machine, measured in Newtons (N). Each group was subdivided into varus load, valgus, extension, flexion, external rotation and internal rotation. An analysis of the data was performed comparing the subgroups of the FL group with their respective subgroups of the Fi group through the two-tailed t test. Results The two-tailed t test showed that in 4 of the 6 evaluated conditions there was no significant statistical difference between the groups (p > 0.05). We have found a significant difference between the group with extension load with a mean of 19 N (FL group) and of 28.7 N (Fi group) (p = 0.004), and also between the groups with flexural load with themean of the forces recorded in the FL group of 17.1 N and of 22.9 N in the Fi group (p = 0.01). Conclusion Fixation with one intramedullary wire and one lateral wire, considering loads in extension and flexion, presents greater stability when compared to a fixation with two lateral wires, suggesting similar clinical results.


Resumo Objetivo Analisar através de ensaios mecânicos a estabilidade da fixação da fratura supracondiliana do úmero com dois fios de Kirschner, intramedular e lateral (Fi), comparada à fixação com dois fios laterais paralelos (FL) em modelos anatômicos, de forma a se definir qual configuração apresenta maior estabilidade. Métodos Foram utilizados como corpos de prova 72 úmeros sintéticos, os quais foram seccionados transversalmente para simular a fratura. Estes ossos foram divididos em dois grupos iguais e as fraturas fixadas com dois fios de Kirschner paralelos (FL) e com um fio lateral e outro intramedular (Fi). Então os corpos de prova foram submetidos aos testes de carga em estresse em uma máquina de ensaio universal, medidos em Newtons (N). Cada grupo foi subdividido em carga em varo, em valgo, em extensão, em flexão, em rotação externa e em rotação interna. A análise dos dados foi realizada comparando os subgrupos do grupo FL, com seus respectivos subgrupos do grupo Fi através do teste t bicaudal. Resultados O teste t bicaudal demonstrou que em 4 das 6 condições aplicadas não houve diferença estatística significativa entre os grupos (p > 0,05). Encontramos uma diferença significativa entre os grupos com carga em extensão com uma média das maiores forças no grupo FL de 19 N e no grupo Fi de 28,7 N (p = 0,004), e também entre os grupos comcarga emflexão coma média de forças registradas no grupo FL de 17,1 N e no grupo Fi de 22,9 N (p = 0,01). Conclusão A fixação com fio intramedular e umfio lateral para cargas em extensão e flexão apresenta maior estabilidade quando comparada com a fixação com dois fios laterais paralelos, sugerindo resultados clínicos no mínimo semelhantes.


Subject(s)
Biomechanical Phenomena , Epiphyses/injuries , Fracture Fixation , Humeral Fractures
12.
Coluna/Columna ; 18(2): 98-100, June 2019. tab, graf
Article in English | LILACS | ID: biblio-1011947

ABSTRACT

ABSTRACT Objectives: The topography of the high cervical spine involves several traumatic, degenerative, and rheumatologic pathologies. With the evolution of surgical techniques and synthesis materials available for use in such region, an optimization of the anatomical understanding of this area is required. Methods: Therefore, this study evaluated 62 computed tomographies of the high cervical spine in an adult population, aiming at the study of the anatomical parameters of the axis pedicle. The measures analyzed in this observational study were pedicle length at axial section, pedicle length at sagittal section, pedicle thickness at axial section and interpedicular angulation. Results: Computed tomography is a necessary exam for the programming of C2 pedicle screws and is useful for determining the anatomical changes and evaluating the length of the screws that will be used. Furthermore, no statistically significant difference was observed in the length, angulation, and diameter of the pedicles of the axis in relation to sex or age. Conclusion: Regarding sex and age, no statistically significant difference on length, angulation, and pedicle diameter occur. There is an urgent need for computed tomography for surgical planning. Level of Evidence II; Transversal Diagnostic Studies - Investigation of a Diagnosis Test.


RESUMO Objetivos: A topografia da coluna cervical alta envolve diversas patologias de cunho traumático, degenerativo e reumatológico. Com a evolução de técnicas cirúrgicas e de materiais de síntese disponíveis para uso em tal região, é necessária uma otimização do entendimento anatômico desta área. Métodos: Assim, este estudo avaliou 62 tomografias computadorizadas da coluna cervical alta na população adulta, visando o estudo dos parâmetros anatômicos do pedículo do Áxis. Comprimento do pedículo no corte axial, comprimento do pedículo no corte sagital, espessura do pedículo no corte axial e angulação interpedicular foram as medidas analisadas neste estudo observacional. Resultados: A tomografia computadorizada mostra-se como um exame necessário para a programação da passagem de parafusos pediculares de C2, sendo útil para determinar as alterações anatômicas e avaliar o comprimento dos parafusos que irão ser utilizados. Também, não foram observadas diferenças estatisticamente significantes no comprimento, angulação e diâmetro dos pedículos do áxis em relação ao sexo. Conclusão: Não foram observadas diferenças estatisticamente significantes no comprimento, na angulação e no diâmetro dos pedículos. Urge a necessidade da Tomografia Computadorizada para o planejamento cirúrgico. Nível de Evidência II; Estudos Transversais de diagnósticos - Investigação de um exame para diagnóstico.


RESUMEN Objetivos: La topografía de la columna cervical alta involucra diversas patologías de origen traumático, degenerativo y reumatológico. Con la evolución de técnicas quirúrgicas y de materiales de síntesis disponibles para uso en tal región, es necesaria una optimización del entendimiento anatómico de esta área. Métodos: Así, este estudio evaluó 62 tomografías computarizadas de columna cervical alta en una población adulta, visando el estudio de los parámetros anatómicos del pedículo de axis. Las medidas analizadas en este estudio observacional fueron la longitud del pedículo en corte axial, la longitud del pedículo en corte sagital, el espesor del pedículo en corte axial y la angulación interpedicular. Resultados: La tomografía computarizada se muestra como un examen necesario para la programación del paso de tornillos pediculares de C2, siendo útil para determinar los cambios anatómicos y evaluar la longitud de los tornillos que se van a utilizar. Además, no se observó diferencias estadísticamente significativas en la longitud, angulación y diámetro de los pedículos del áxis en relación al sexo. Conclusión: En relación al sexo y edad no ocurren diferencias estadísticamente significativas en la longitud, la angulación y el diámetro de los pedículos. Urge la necesidad de la tomografía computarizada para la planificación quirúrgica. Nivel de Evidencia II; Estudios transversales de diagnóstico - Investigación de un examen para diagnóstico.


Subject(s)
Humans , Axis, Cervical Vertebra , Tomography, X-Ray Computed
13.
Coluna/Columna ; 18(2): 144-150, June 2019. tab, graf
Article in English | LILACS | ID: biblio-1011948

ABSTRACT

ABSTRACT Objective: This study aims to numerically evaluate the surgical treatment of thoracolumbar fractures, comparing the strengths between the long and short fixations using the pedicle of the fractured vertebra, taking into account the supraspinous, intertransverse, and anterior longitudinal ligaments. Methods: A numerical analysis of the techniques of long and short fixation of a thoracolumbar spine fracture was performed using computed tomography images that were converted into three-dimensional models and analyzed through the ANSYS program. The two types of treatments were analyzed considering the tensions generated in the immediate postoperative period, when the fracture has not yet been consolidated. The anterior, posterior, supraspinal and intertransverse longitudinal ligaments were added, in addition to considering different vertebral geometries. Results: Taking into account that the maximum tensile stress of the material used in the metal implant, in the case of titanium, was 960 MPa, the highest tension found in the analysis of the short instrumentation was 346.83 MPa, reaching only 36.13% of the load the material supports, being, therefore, within a safety limit. The analysis performed in the spine with long instrumentation showed the highest tension value of 229.22 MPa. Conclusions: Considering the values found and the resistance of the synthesis material used, the short and long fixation can be considered in the treatment of thoracolumbar fractures with similarity and a good safety coefficient. Level of Evidence III; Case-Control.


RESUMO Objetivo: Este trabalho tem como objetivo avaliar numericamente o tratamento cirúrgico das fraturas toracolombares, comparando a resistências entre as fixações longas e curtas usando o pedículo da vértebra fraturada, levando-se em conta os ligamentos supra-espinhal, intertransversal e longitudinal anterior. Métodos: Foi realizada uma análise numérica das técnicas de fixação longa e curta deumafratura da coluna toracolombar, utilizando-se imagens de tomografia computadorizada que foram convertidas em modelos tridimensionais e analisados através do programa ANSYS. Os dois tipos de tratamentos foram analisados considerando-se as tensões geradas no período pós operatório imediato, quando a fratura ainda não está consolidada. Foram adicionados os ligamentos longitudinal anterior, posterior, supra-espinhal e intertransversal, além de se considerar diferentes geometrias vertebrais. Resultados: Levando em consideração que a tensão máxima de ruptura do material utilizado no implante metálico, no caso o titânio, ser de 960 MPa, a maior tensão encontrada na análise da instrumentação curta foi de 346,83 MPa, atingindo apenas 36,13% da carga que o material suporta, estando, portanto, dentro de um limite de segurança. A análise realizada na coluna com instrumentação longa verificou o valor de tensão mais elevado de 229,22 MPa. Conclusão: Considerando os valores encontrados e a resistência do material de síntese utilizado, a utilização da fixação curta e longa podem ser consideradas no tratamento das fraturas toracolombares apresentando similaridade e um bom coeficiente de segurança. Nível de Evidência III; Caso-Controle.


RESUMEN Objetivo: Este trabajo tiene como objetivo evaluar numéricamente el tratamiento quirúrgico de las fracturas toracolumbares, comparando las resistencias entre las fijaciones largas y cortas usando el pedículo de la vértebra fracturada, teniendo en cuenta los ligamentos supraespinal, intertransverso y longitudinal anterior. Métodos: Se realizó un análisis numérico de las técnicas de fijación larga y corta de una fractura de la columna toracolumbar, utilizando imágenes de tomografía computarizada que se convirtieron en modelos tridimensionales y fueron analizadas con el programa ANSYS. Los dos tipos de tratamiento fueron analizados considerando las tensiones generadas en el período postoperatorio inmediato, cuando la fractura aún no está consolidada. Se añadieron los ligamentos longitudinal anterior, posterior, supraespinal e intertransverso, además de considerar diferentes geometrías vertebrales. Resultados: Teniendo en cuenta que la tensión máxima de ruptura del material utilizado en el implante metálico, en el caso el titanio, fue de 960 MPa, la mayor tensión encontrada en el análisis de la instrumentación corta fue de 346,83 MPa, alcanzando apenas el 36,13% de la carga que el material soporta, estando, por lo tanto, dentro de un límite de seguridad. El análisis realizado en la columna con instrumentación larga mostró el valor de tensión más elevado de 229,22 MPa. Conclusiones: Teniendo en cuenta los valores encontrados y la resistencia del material de síntesis utilizado, la utilización de la fijación corta y larga puede ser considerada en el tratamiento de las fracturas toracolumbares presentando similitud y un buen coeficiente de seguridad. Nivel de Evidencia III, Caso-Controle.


Subject(s)
Humans , Orthopedics , Spine , Surgical Procedures, Operative , Finite Element Analysis , Fractures, Bone
14.
Rev. bras. ortop ; 54(2): 183-189, Mar.-Apr. 2019. tab, graf
Article in English | LILACS | ID: biblio-1013704

ABSTRACT

Abstract Objective The present study aims to evaluate different methods of tibial fixation in the reconstruction of the anterolateral ligament (ALL). In addition, the present paper aims to compare the effectiveness of these methods and theirmechanisms of failure in swine knees. Methods A total of 40 freshly frozen swine limbs were divided into 4 groups of 10 specimens, according to the tibial fixation technique used. In group A, the tibial fixation of the tendon graft wasmade through an anchor passing the graft. In group B, the tibial fixation was performed through a metal interference screw in a single bone tunnel. In group C, the tibial fixation included an anchor associated with a tendinous suture (but not with a wire crossing the tendon). In group D, two confluent bony tunnels were drilled and combined with an interference screw in one of them. Results The lowest mean force (70.56 N) was observed in group A, and the highest mean force (244.85 N) was observed in group B; the mean values in the other 2 groups ranged from 171.68 N (group C) to 149.43 N (group D). Considering the margin of error (5%), there was a significant difference between the groups (p < 0.001). Conclusion Fixation with an interference screw in a single tunnel bone showed the highest tensile strength among the evaluated techniques.


Resumo Objetivo Avaliar a força de resistência à tração de diferentesmétodos de fixação tibial na reconstrução do ligamento anterolateral (LAL). Além disso, comparar os mecanismos de falha da fixação tibial dessa reconstrução em joelhos suínos. Métodos Foram usados 40 membros recém-congelados de suínos, divididos em quatro grupos de dez espécimes, conforme as técnicas de fixação tibial usadas. No grupo A, a fixação tibial do enxerto tendíneo foi feita por meio de uma âncora e seu fio transpassou o enxerto. No grupo B, a fixação tibial foi feita por meio de parafuso de interferência metálico em túnel ósseo único. No grupo C, a fixação tibial incluiu uma âncora associada à sutura de ponto sobre o tendão (sem a presença de fio que transpassasse o tendão) e, no grupo D, foram usados dois túneis ósseos confluentes associados a um parafuso de interferência em um dos túneis. Resultados A força média menos elevada (70,56 N) ocorreu no grupo A e a mais elevada (244,85 N), no grupo B; as médias dos outros dois grupos variaram entre 171,68N (grupo C) e 149,43 N (Grupo D). Considerando-se a margem de erro fixada (5%), foi observada diferença significativa entre os grupos (p < 0,001). Conclusão A fixação com parafuso de interferência em túnel ósseo único apresentou a maior força de resistência à tração dentre as técnicas avaliadas. Abstract Objective The present study aims to evaluate different methods of tibial fixation in the reconstruction of the anterolateral ligament (ALL). In addition, the present paper aims to compare the effectiveness of these methods and theirmechanisms of failure in swine knees.


Subject(s)
Animals , Anterior Cruciate Ligament , Orthopedic Procedures , Knee , Ligaments, Articular
15.
Rev. bras. ortop ; 53(1): 82-87, Jan.-Feb. 2018. tab
Article in English | LILACS | ID: biblio-899229

ABSTRACT

ABSTRACT Objective: The purpose of this study is to evaluate the performance of dynamic hip screw for the treatment of dislocated femoral neck fractures in young patients, focusing on osteonecrosis. Methods: A series of 53 patients with less than 55 years of age were retrospectively evaluated. All patients had dislocated femoral neck fractures (Garden III or IV) and were treated with DHS. Ficat's staging system was used to evaluate avascular necrosis. Results: There were 38 (71.7%) males and 15 (28.3%) females, with an overall mean age at the onset of fracture of 41.9 years (±12.8). According to Garden's classification, 21 (39.6%) fractures were classified as type III and 32 (60.4%) were considered totally dislocated, Garden IV. Fracture healing was achieved in 39 patients (73.6%). Thirteen cases of avascular necrosis were observed (24.6%). Conclusions: The incidence of avascular necrosis in young patients with a displaced femoral neck fractures treated with DHS was 24.6%. No statistically significant association was found between times elapsed to surgery, fracture displacement, and presence of derotation screw with osteonecrosis. Level of evidence IV.


RESUMO Objetivo: Avaliar o desempenho do dynamic hip screw (DHS) no tratamento de fraturas do colo femoral deslocadas em pacientes jovens, com foco na osteonecrose. Métodos: Uma série de 53 pacientes com menos de 55 anos foi avaliada retrospectivamente. Todos os pacientes apresentaram fraturas do colo femoral deslocadas (Garden III ou IV) e foram tratados com DHS. O sistema de estadiamento de Ficat foi usado para avaliar a necrose avascular. Resultados: Foram incluídos 38 (71,7%) pacientes do sexo masculino e 15 (28,3%) do feminino, com média no momento da fratura de 41,9 anos (± 12,8). Segundo a classificação de Garden, 21 (39,6%) fraturas foram classificadas como tipo III e 32 (60,4%) foram considerados totalmente deslocadas, Garden IV. A consolidação da fratura foi obtida em 39 pacientes (73,6%). Foram observados 13 casos de necrose avascular (24,6%). Conclusões: A incidência de necrose avascular em pacientes jovens com fraturas deslocadas do colo do fêmur tratados com DHS foi de 24,6%. Não houve associação estatisticamente significante entre os intervalos até a cirurgia, o deslocamento da fratura e a presença de parafuso antirrotacional com a osteonecrose. Nível de evidência IV.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Bone Screws , Femoral Neck Fractures/pathology , Femoral Neck Fractures/surgery
16.
Rev. bras. ortop ; 53(1): 118-124, Jan.-Feb. 2018. tab, graf
Article in English | LILACS | ID: biblio-899231

ABSTRACT

ABSTRACT This article aims to report four cases of unstable pelvic fractures in pregnant women treated by open reduction and internal fixation. Cases report: The study included four cases of pregnant women with unstable pelvic fractures; their outcomes were analyzed and discussed. Data were obtained from two University Hospitals. The mean age of women was 23 years; most (3/4) were primiparous, with a mean pregnancy age of 23 weeks. Two women had Malgaigne-type fractures and the other two had symphyseal disjunction associated with acetabular fractures. All fractures were treated surgically. One foetus was dead on admission to hospital. The other three developed well, along with their mothers. Good evolution was only possible with careful pre-, peri-, and postoperative care for the mother, as well as foetal assessment by a multidisciplinary team. In complex cases such as those presented in the present study, pre-, peri-, and postoperative care are mandatory, as well as the presence of a multidisciplinary team. The mother's life always takes priority in acute clinical pictures, as it offers the best chance of survival to both mother and child.


RESUMO O objetivo deste trabalho é relatar quatro casos de fraturas pélvicas instáveis em grávidas tratadas com redução aberta e fixação interna. Relato dos casos: Foram considerados neste estudo quatro casos de gestantes com fraturas instáveis da pelve, foram analisados e discutidos os seus desfechos. Os dados foram obtidos em dois hospitais universitários. A idade média das mulheres foi de 23 anos. A maioria delas (3/4) era primípara, com idade gestacional média de 23 semanas. Duas mulheres tiveram fraturas do tipo Malgaigne e as outras duas apresentaram disjunção da sínfise associada a fraturas do acetábulo. Todas as fraturas foram tratadas cirurgicamente. Um feto estava morto no momento da admissão ao hospital. Os outros três evoluíram bem, junto com suas mães. A boa evolução dos quadros só foi possível com o cuidado pré-, peri- e pós-operatório das gestantes e com a avaliação dos fetos por uma equipe multidisciplinar. Em casos complexos como os abordados neste artigo, são imprescindíveis os cuidados pré-, peri- e pós-operatórios, além da presença de uma equipe multidisciplinar. A vida da mãe tem sempre prioridade no quadro agudo, pois oferece a melhor chance de sobrevivência para a mãe e a criança.


Subject(s)
Humans , Female , Pregnancy , Adult , Fractures, Bone , Pelvic Bones
17.
Rev. Col. Bras. Cir ; 45(5): e1985, 2018. tab
Article in Portuguese | LILACS | ID: biblio-976928

ABSTRACT

RESUMO Objetivo: comparar dados clínicos, laboratoriais e densitométricos de pacientes com osteoartrose e com fratura do colo femoral. Métodos: estudo transversal de pacientes com fratura do colo femoral e osteoartrose do quadril, submetidos à artroplastia de quadril. Dados clínicos, laboratoriais e densitométricos foram coletados. Resultados: cinquenta e três pacientes foram incluídos, 22 com fraturas do colo femoral e 31 com osteoartrose. Pacientes com fratura do colo do fêmur apresentaram maior idade do que os pacientes com osteoartrose, tendo valores de IMC, densidade mineral óssea e força de preensão palmar (pacientes sarcopênicos) inferiores, estando mais incapacitados neurologicamente e apresentando um pior escore ASA. Entre os vários parâmetros bioquímicos analisados, diferenças estatisticamente significantes foram encontrados no cálcio sérico total, cálcio ionizado, vitamina D, tiroxina livre, eritrócitos, hemoglobina, hematócrito, glóbulos brancos totais, neutrófilos, linfócitos e creatinina entre os dois grupos. Outros hormônios analisados e parâmetros bioquímicos não diferiram significativamente, apesar de mostrarem tendências entre os dois grupos. Conclusão: pacientes com fraturas do colo do fêmur são mais idosos do que pacientes com osteoartrose, apresentam um menor peso e IMC, são mais debilitados, muitos com anemia e massa óssea reduzida, além de terem uma diminuição significativa no cálcio total, cálcio ionizado, vitamina D e creatinina e um aumento significativo na tiroxina livre.


ABSTRACT Objective: to compare clinical, laboratory and densitometric data from patients with osteoarthrosis and femoral neck fractures. Methods: we conducted a cross-sectional study of patients with femoral neck fracture and hip osteoarthrosis submitted to hip arthroplasty. We collected clinical, laboratory and densitometric data. Results: we included 53 patients, 22 with femoral neck fractures and 31 with osteoarthrosis. Patients with femoral neck fractures were older than patients with osteoarthrosis, with lower BMI values, bone mineral density and palmar grip strength (sarcopenic patients), being more neurologically impaired and presenting a worse ASA score. Among the various biochemical parameters analyzed, we found statistically significant differences in total serum calcium, ionized calcium, vitamin D, free thyroxine, erythrocytes, hemoglobin, hematocrit, total white blood cells, neutrophils, lymphocytes and creatinine between the two groups. Other hormones analyzed and biochemical parameters did not differ significantly, although they showed trends between the two groups. Conclusion: patients with femoral neck fractures are older than patients with osteoarthrosis, have a lower weight and BMI, are more debilitated, many with anemia and reduced bone mass, and have a significant decrease in total calcium, ionized calcium, vitamin D and creatinine and a significant increase in free thyroxine.


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Biomarkers/blood , Osteoarthritis, Hip/surgery , Arthroplasty, Replacement, Hip , Femoral Neck Fractures/surgery , Osteoarthritis, Hip/blood , Body Mass Index , Bone Density , Cross-Sectional Studies , Treatment Outcome , Femoral Neck Fractures/blood , Middle Aged
18.
Acta ortop. bras ; 23(6): 323-325, tab, graf
Article in English | LILACS | ID: lil-764405

ABSTRACT

ABSTRACTTotal hip arthroplasty (THA) is one of the most cost-effective hip surgeries among orthopedic procedures. We conducted an extensive literature review with 5,394 papers regarding survival rates after THA. We searched PubMed, Embase and the Cochrane library from January 1st, 1970 to July 31th, 2014 looking for all citations about total hip arthroplasty with a long term follow-up (longer than 10 years). The criteria were rigorous: no loss of follow-up, and follow-up more than 10 years. The authors should have known the complete history of patients (whether the patient is alive or dead). Considering the criteria, we found only 15 papers. To evaluate the relationship between follow-up and survival, a linear regression analysis was applied. Considering the papers analysed, and applying the search criteria, we obtained a mean age for the patients above 57.5 years. The chance of survival at 15 years was 57.6%, at 20 years it was 34.6% and at 25 years it is only 11.6%. The relationship between follow-up and survival was significantly linear (p <0.001). Only 11.6% of patients undergoing THA will be still alive 25 years after the surgical procedure. Level of Evidence I, Prognostic Study.

19.
Acta ortop. bras ; 23(6): 319-322, graf
Article in English | LILACS | ID: lil-764407

ABSTRACT

ABSTRACTOBJECTIVE: The purpose of this study was to evaluate the performance of valgus intertrochanteric osteotomy in femoral neck non-union.METHODS: Forty-two patients with femoral neck fractures with non-union treated using Pauwels' intertrochanteric osteotomy were reviewed. Demographics, time elapsed between fracture and surgery, follow--up, osteosynthesis used, Garden's classification, limb shortening, and x-rays were evaluated.RESULTS: Twenty-two men and 20 women were reviewed. The youngest patient was 18 years old and the oldest 65 years old, with a mean age of 42.4 years (±11.2). The minimum follow-up was 2 years, with a mean of 10.2 years. The average time elapsed between initial fracture and osteotomy was 6.5 months. Twel-ve cases were neglected femoral neck fractures. Nineteen patients were classified as Garden III, and 23 patients as Garden IV. After valgus osteotomy, non-union healing was observed in 38 patients (38/42; 90.4%). Healing of thirty-seven cases of pseudoarthrosis were obtained after the first-attempt osteotomy, and one case required two operations for healing. The osteotomy failed in four cases. Conside-ring the healed osteotomies, good to excellent functional results were achieved in 80.9% (34/42) of the patients. Total hip replacement was subsequently performed in 14.2% (6/42) of the patients for unfavoura-ble outcomes (two for cutting out, two for osteonecrosis, and two for osteoarthritis).CONCLUSIONS: Valgus intertrochanteric osteotomy has a high success rate in archiving healing in femoral neck non-union with good functional results. It is a biological and effective method. Level of Evidence IV, Therapeutic Study.

20.
Acta ortop. bras ; 23(5): 268-270, Sep.-Oct. 2015. tab, graf
Article in English | LILACS | ID: lil-762856

ABSTRACT

Objetivo: Avaliar o sangramento da cabeça femoral em quadris queapresentam osteoartrose durante o procedimento cirúrgico de artroplastiatotal do quadril. Métodos: Foram avaliados 103 quadris acometidospor osteoartrose coxofemoral primária. Após a luxação cirúrgica, a cabeçafemoral foi dividida em quatro quadrantes onde eram realizadasmicroperfurações com a finalidade de observar e qualificar a presençade sangramento como tipo precoce (SP), tardio (ST) ou sem sangramento(SS). Resultados: Foi observado no quadrante superior sangramentoprecoce (SP) em 16 quadris (15.5%), sangramento tardio em 14quadris (13.6%) e não houve sangramento (SS) em 73 quadris (70.9%).No quadrante anterior, foi observado SP em 24 quadris (23.3%), ST em7 quadris (6.8%) e SS em 72 quadris (69.9%). No quadrante inferior, foidetectado SP em 40 quadris (38.8%), ST em 14 quadris (13.6%) e SSem 49 quadris (47.6%). Finalmente, no quadrante posterior, havia SPem 39 quadris (37.9%), ST em 19 quadris (18.4%) e SS em 45 quadris(43.7%). Comparando o IMC e gênero dos participantes, não encontramosnenhuma associação (p>0,05). Conclusões: Os quadrantes inferiore posterior apresentaram maior sangramento, seguindo o trajeto daartéria circunflexa medial. Nível de Evidência III, Estudo Terapêutico.


Objective: To evaluate the bleeding of the femoral head on hiposteoarthritis in patients who underwent total hip arthroplasty.Methods: One hundred and three hips affected by primary hiposteoarthritis were evaluated. After surgical dislocation, the femoralhead was divided into four quadrants, and micro perforations weremade in order to observe and assess the presence of bleeding, asearly type (EB), late type (LB) or without bleeding (WB). Results:We observed early bleeding (EB) in the upper quadrant in 16hips (15.5%), late bleeding in 14 hips (13.6%) and no bleeding(WB) in 73 hips (70.9%). The anterior quadrant showed EB in 24hips (23.3%), LB in 7 hips (6.8%) and WB in 72 hips (69.9%).The lower quadrant presented EB in 40 hips (38.8%), LB 14 hips(13.6%) and WB in 49 hips (47.6%). The posterior quadrant showedEB in 39 hips (37.9%), LB 19 hips (18.4%) and WB in 45 hips(43.7%). Comparing BMI and gender, we found no associationbetween these parameters (p> 0.05). Conclusions: The inferiorand posterior quadrant had the highest bleeding levels, followingthe path of the medial circumflex artery. Level of Evidence III,Therapeutic Study.


Subject(s)
Humans , Male , Female , Middle Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip , Blood Loss, Surgical , Femur Head , Hip Prosthesis , Osteoarthritis/surgery
SELECTION OF CITATIONS
SEARCH DETAIL